Below you will find a list of common error messages from various brands. Not all error messages are listed here. It is advisable to also consult the manual of the device.

Brand Error code Cause Action
______________ ____________________________ _________________________ ________________________________________________________
MASTERVOLT XS SOL 1 LOW DC Low Check the manual and measure/check the pv-system
MASTERVOLT XS COUNTRY Country settings Check the manual and measure/check the pv-system
MASTERVOLT XS TEMP HI Internal temperature too high Check the manual and measure/check the pv-system
MASTERVOLT XS SOL 1 HIGH DC High Check the manual and measure/check the pv-system
MASTERVOLT XS NO GRID Grid error Check the manual and measure/check the pv-system
MASTERVOLT XS ENS OFF ENS Error Contact inverter service
MASTERVOLT XS G83 OFF G83 Error Check the manual and measure/check the pv-system
MASTERVOLT XS VAC LOW Grid Low Check the manual and measure/check the pv-system
MASTERVOLT XS VAC HIGH Grid High Check the manual and measure/check the pv-system
MASTERVOLT XS FAC LOW Frequency Low Check the manual and measure/check the pv-system
MASTERVOLT XS FAC HIGH Frequency High Check the manual and measure/check the pv-system
MASTERVOLT XS INSULATION Isolation Check the manual and measure/check the pv-system
MASTERVOLT XS NTC FAIL Internal fault Contact inverter service
MASTERVOLT XS EF I2C FAIL Internal fault Contact inverter service
MASTERVOLT XS ENS FAIL Internal fault Contact inverter service
MASTERVOLT XS CB I2C FAIL Internal fault Contact inverter service
MASTERVOLT XS HW VAC FAC Internal fault Contact inverter service
MASTERVOLT XS HW RELAY Internal fault Contact inverter service
MASTERVOLT XS HW ERROR 0 Internal fault Contact inverter service
MASTERVOLT XS HW ERROR 02 Internal fault Contact inverter service
MASTERVOLT XS HW ERROR 03 Internal fault Contact inverter service
MASTERVOLT XS HW ERROR 04 Internal fault Contact inverter service
MASTERVOLT XS HW ERROR 05 Internal fault Contact inverter service
MASTERVOLT XS HW ERROR 06 Internal fault Contact inverter service
MASTERVOLT Geen display Internal fault Contact inverter service
MASTERVOLT CS AC freq high, low Frequency error Check the manual and measure/check the pv-system
MASTERVOLT CS AC phase jump Frequency error Check the manual and measure/check the pv-system
MASTERVOLT CS AC quality Grid error Check the manual and measure/check the pv-system
MASTERVOLT CS AC volt low Grid Low Check the manual and measure/check the pv-system
MASTERVOLT CS AC volt high Grid High Check the manual and measure/check the pv-system
MASTERVOLT CS TR AC volt high Grid error Check the manual and measure/check the pv-system
MASTERVOLT CS SL AC volt high Grid High Check the manual and measure/check the pv-system
MASTERVOLT CS AC Phace Balance Grid error Check the manual and measure/check the pv-system
MASTERVOLT CS HW Unbalance Internal fault Contact inverter service
MASTERVOLT CS HW CTA Internal fault Contact inverter service
MASTERVOLT CS HW BUS OVERVOLTAGE Internal fault Contact inverter service
MASTERVOLT CS HW DC INJECT Internal fault Contact inverter service
MASTERVOLT CS ERROR 30 Internal fault Contact inverter service
MASTERVOLT CS ERROR 33 Internal fault Contact inverter service
MASTERVOLT CS HW ERROR Internal fault Contact inverter service
MASTERVOLT CS OVP1 Internal fault Check the manual and measure/check the pv-system
MASTERVOLT CS OVP2 Internal fault Check the manual and measure/check the pv-system
MASTERVOLT XL Diagnostic en On led Grid error Check the manual and measure/check the pv-system
MASTERVOLT XL Diagnostic en 25% DC High Check the manual and measure/check the pv-system
MASTERVOLT XL Diagnostic en 50% Grid error Check the manual and measure/check the pv-system
MASTERVOLT XL Diagnostic en 75% Temperature Error Contact inverter service
MASTERVOLT XL Diagnostic en 100% Insulation Check the manual and measure/check the pv-system
MASTERVOLT XL Diagnostic en knipperen Internal fault Contact inverter service
MASTERVOLT XL ERROR Internal fault Contact inverter service