Below you will find a list of common error messages from various brands. Not all error messages are listed here. It is advisable to also consult the manual of the device.

Brand Error code Cause Action
______________ ____________________________ _________________________ ________________________________________________________
DELTA SOLIVIA HW DC Injection Internal fault Contact inverter service
DELTA SOLIVIA TEMPERATURE Internal temperature too high Check the manual and measure/check the pv-system
DELTA SOLIVIA HW NTC1 FAIL Internal temperature too high Check the manual and measure/check the pv-system
DELTA SOLIVIA HW NTC2 FAIL Internal temperature too high Check the manual and measure/check the pv-system
DELTA SOLIVIA HW NTC3 FAIL Internal temperature too high Check the manual and measure/check the pv-system
DELTA SOLIVIA HWNTC4 FAIL Internal temperature too high Check the manual and measure/check the pv-system
DELTA SOLIVIA Relay test open Internal fault Contact inverter service
DELTA SOLIVIA firmware Fail Internal fault Contact inverter service
DELTA SOLIVIA HW DSP ADC1 Internal fault Contact inverter service
DELTA SOLIVIA HW DSP ADC2 Internal fault Contact inverter service
DELTA SOLIVIA HW DSP ADC3 Internal fault Contact inverter service
DELTA SOLIVIA HW RED ADC1 Internal fault Contact inverter service
DELTA SOLIVIA HW RED ADC2 Internal fault Contact inverter service
DELTA SOLIVIA HW Efficienty Internal fault Contact inverter service
DELTA SOLIVIA HW FAN Check Cooling Check the manual and measure/check the pv-system
DELTA SOLIVIA HW COMM2 Internal fault Contact inverter service
DELTA SOLIVIA HW COMM1 Internal fault Contact inverter service
DELTA SOLIVIA Ground Current Check System Check the manual and measure/check the pv-system
DELTA SOLIVIA Insulation Insulation problem Check the manual and measure/check the pv-system
DELTA SOLIVIA HW Connect Fail Internal fault Contact inverter service
DELTA SOLIVIA RCMU Fail Internal fault Contact inverter service
DELTA SOLIVIA Rerlay test short Internal fault Contact inverter service
DELTA SOLIVIA Bus Unbalance Internal fault Contact inverter service
DELTA SOLIVIA HW Bus OVR Internal fault Contact inverter service
DELTA SOLIVIA HW BUS UVR Internal fault Contact inverter service
DELTA SOLIVIA AC Curren tHigh Internal fault Contact inverter service
DELTA SOLIVIA HW CT A Fail Internal fault Contact inverter service
DELTA SOLIVIA HW CT B Fail Internal fault Contact inverter service
DELTA SOLIVIA HW CT C Fail Internal fault Contact inverter service
DELTA SOLIVIA HW AC OCR Internal fault Contact inverter service
DELTA SOLIVIA Inverter Failure Internal fault Contact inverter service
DELTA SOLIVIA HW ZC Fail Internal fault Contact inverter service
DELTA SOLIVIA DC Current High Internal fault Contact inverter service
DELTA SOLIVIA AC Freq High Grid error Check the manual and measure/check the pv-system
DELTA SOLIVIA AC Freq Low Grid error Check the manual and measure/check the pv-system
DELTA SOLIVIA Phase Jump Internal fault Contact inverter service
DELTA SOLIVIA Grid Quality Grid error Check the manual and measure/check the pv-system
DELTA SOLIVIA No Grid Grid error Check the manual and measure/check the pv-system
DELTA SOLIVIA AC Volt Low Grid error Check the manual and measure/check the pv-system
DELTA SOLIVIA AC Volt High Grid error Check the manual and measure/check the pv-system
DELTA SOLIVIA 3Phase Unbalance Internal fault Contact inverter service
DELTA SOLIVIA Solar1High Check System Check the manual and measure/check the pv-system
DELTA SOLIVIA Solar2High Check System Check the manual and measure/check the pv-system